Guangdun Door Industry Co., Ltd. Jindi Fire Door Project Overview
- Fire Door Project Overview
- Building Area: 11,771 m², with one basement and two floors above ground.
- Structural Form: Frame-shear wall structure with a first-class fire resistance rating.
- Fire-Resistant Steel Doors: The door frame, panel, and reinforcement components are made from electro-galvanized steel. Single-leaf doors are equipped with door closers, while double-leaf doors have cover plates and door closers. The fire resistance limits are as follows:
- Grade A Steel Fire Doors: Fire resistance of no less than 1.2 hours.
- Grade B Steel Fire Doors: Fire resistance of no less than 0.9 hours.
- Grade C Steel Fire Doors: Fire resistance of no less than 0.6 hours.
- Regulatory Basis The project follows several key regulations and standards:
- General Technical Conditions for Steel Fire Doors (GB12955-1991).
- Building Fire Protection Design Code (GBJ16-87).
- Unified Construction Quality Acceptance Standards (GB50300-2001).
- Building Decoration and Renovation Quality Standards (ZJQ00-SG-021-2006).
- Building Energy Efficiency Quality Standards (GB50411-2007).
- Indoor Air Quality Control for Civil Buildings (GB50325-2001).
- Construction Preparations 3.1 Technical Preparation
- Thoroughly understand the installation locations and site conditions.
- Fire Door Installation Locations & Fire Resistance Levels:
- Grade A Fire Doors: Fire compartment doors, electrical equipment room doors with a 1.2-hour fire resistance.
- Grade B Fire Doors: Staircase and lobby doors with a 0.9-hour fire resistance.
- Grade C Fire Doors: Pipe room access doors with a 0.6-hour fire resistance.
- All materials must be accompanied by certificates of quality, inspection reports, and eco-labels. Materials should be protected from sunlight, rain, and moisture, especially for wooden fire doors.
- Fire Door Transport: Ensure doors are securely packed to prevent surface scratches and ensure safe handling.
- On-Site Storage: Store fire doors on wooden pallets to prevent contact with the ground and protect them from moisture and impact.
- A variety of tools, such as wood wedges, impact drills, expansion bolts, measuring tapes, and welding tools, are necessary for accurate installation and adjustments during the fire door installation process.
- Installation Process
- Process Flow: Marking, door frame installation, temporary fixation, door leaf installation, and hardware fittings.
- Steel Fire Door Installation:
- Marking and Positioning: Mark door frame locations based on design specifications.
- Frame Installation: Ensure the door frame is square, vertical, and positioned correctly with gaps between the frame and wall sealed with cement mortar.
- Door Frame Fixing: Secure the frame with galvanized connectors and expansion bolts.
- Leaf Installation: Attach the door leaf to the frame using proper hinges and adjustments to ensure ease of operation.
- Hardware Fitting: Install locks, handles, and additional fire-resistant features.
- Quality Standards
- Key Quality Control Points:
- The fire doors should meet all the design specifications for material quality, fire resistance rating, and functionality.
- Installation: The door must be firmly installed, and its operation should be smooth with proper sealing upon closing.
- Mechanical Devices: Fire doors with automatic or smart features must meet the required standards for performance and reliability.
- Dimension Tolerances: Fire doors must adhere to strict dimensional tolerances:
- Door Height: ±2 mm
- Door Width: ±3 mm
- Door Thickness: ±2 mm
- Frame Slot Dimensions: ±3 mm
- Frame Side Width: ±2 mm
- Key Quality Control Points:
- Protection Measures
- Ensure fire doors are stored and installed without any risk of surface damage. Protective films should be used to avoid scratches during installation and handling.Fire Door Project Overview.
- After installation, the door should be carefully protected from external damage, such as during finishing work like plastering or painting.
- Safety and Civilized Construction Measures
- Installers must wear safety helmets and follow all safety regulations when using electrical tools and equipment.
- Regular checks should be performed on electrical tools to prevent hazards, ensuring a safe working environment.
- The use of ladders should be secure, and tools should be neatly stored to prevent accidents.
- After-Sales Service Plan Guangdun Door Industry Co., Ltd. guarantees high-quality after-sales service to ensure the continued operation of fire safety systems:
- Service Commitment: Our company ensures that fire doors and related products maintain peak functionality through quality tracking and maintenance services.
- Maintenance Plan: We offer a comprehensive maintenance contract post-project completion, ensuring continued support for the longevity of fire doors and systems.
- Support Staff: We provide highly trained technicians to address any issues that may arise during the service life of the fire doors.
1. Fire Door Classification and Fire Resistance
Level | Name | Location of Use | Fire Resistance Duration (hours) |
---|---|---|---|
Grade A | Fire Door | Fire compartment doors, equipment rooms, and electrical rooms | 1.20 |
Grade B | Fire Door | Staircase doors and front room doors | 0.90 |
Grade C | Fire Door | Pipeline maintenance room doors | 0.60 |
2. Tools and Specifications for Installation
Tool Name | Specification | Quantity | Purpose |
---|---|---|---|
Wood Wedge | 50*300mm | 20 pcs | Fixing the door frame |
Impact Drill | 12 | 1 unit | Drilling expansion bolt holes |
Expansion Bolt | M8*60mm | 16 pcs | Connecting the wall and door frame |
Transparent Water Pipe | Ø10mm, 5m long | 1 piece | Adjusting the door frame level |
Magnetic Plumb Bob | 50 | 1 piece | Adjusting the verticality of the door frame |
Mallet | 1.5 lbs | 1 piece | Adjusting door frame and leaf, installing expansion bolts |
Tape Measure | 5m, 3m | 1 piece | Measuring various lengths |
Wooden Block | 1 piece | 1 piece | Adjusting door leaf warping |
Hinge Shim | Same as hinge size | 6 pieces | Adjusting door gaps |
Baffle Plate | 1004001.5mm | 1 piece | Preventing welding splashes |
Grounding Wire | Φ10*50mm | 16 pieces | Connecting expansion bolts and door frame |
Opening Tool | 14 | 1 piece | Tightening expansion bolts |
Drill Bit | Ø3.2~Ø12 | Several | Drilling holes |
Electric Drill | 10 | 1 piece | Drilling holes |
Round/Flat File | 4 inches | 1 piece | Filing irregular holes and uneven surfaces |
Chisels | 200mm | 1 piece | Chipping weld spots, adjusting reinforcement plate positions |
Flat Screwdriver | 200mm | 1 piece | Installing screws and locks |
Cross Screwdriver | 200mm | 1 piece | Installing screws and locks |
Welding Mask | 1 piece | 1 piece | For welding |
Welding Gloves | 1 pair | 1 pair | For welding |
Power Cable | 50m~100m | 50 meters | For drilling and welding |
3. Measurement Tolerances for Door Components-Fire Door Project Overview
Part Name | Measurement Item | Tolerance (mm) |
---|---|---|
Door Leaf Height | +2, -1 | |
Door Frame Slot Height | ±3 | |
Door Leaf Width | -1, -3 | |
Door Frame Side Width | ±2 | |
Door Leaf Thickness | +2, -1 | |
Door Frame Slot Width | ±1 |
4. Measurement and Tolerances for Door Assembly
Name | Measurement Item | Tolerance (mm) |
---|---|---|
Door Frame | Difference in length of both diagonal slots | ≤3 |
Door Frame | Difference in length of both diagonals | ≤3 |
Door Leaf | Distortion (Warp) | ≤5 |
Door Leaf | Vertical Curvature | ≤2 |
Door Frame, Door Leaf | Height Difference of Door Frame and Door Leaf (Front Surface) | ≤3 |
Let me know if anything needs further adjustments or if you need more translations!
Conclusion: Enhancing Fire Safety with Reliable Fire Doors
At Guangdun Door Industry Co., Ltd., we are committed to producing top-quality fire doors designed to meet rigorous safety standards. By adhering to national and international regulations, we ensure that our fire doors offer the highest level of protection in various buildings, from residential and commercial spaces to industrial facilities.
We pride ourselves on our thorough technical preparation, expert installation process, and comprehensive after-sales service. With years of expertise as a leading fire door manufacturer, we guarantee that our products provide long-lasting fire protection, helping you create safer environments for your buildings.